Just one step from sample to result.

Lab direct qPCR

Our Lab direct qPCR kits enable for fast and sensitive analysis and neither require a complicated multi-step protocol for sample preparation nor for qPCR setup.  

All reagents required are provided in ready-to-use solutions, simply add the sample to the reaction solution and start your run. 

Choose your Lab direct kit

res4plex direct RT-PCR

Differentiate between FLU A/B and relevant respiratory pathogens.

res4plex direct RT-PCR is uniquely designed to detect Influenza A, Influenza B as well as SARS-CoV-2 and human respiratory syncytial virus (RSV) RNA, respectively after extraction on a commercial qPCR cycler.

Product specifications

Ref.-No.: FBC107

FeatureSpecifications
ApplicationIdentification of Influenza A, Influenza B, SARS-CoV-2 (E-Gene/N-Gene) and respiratory syncytial virus (RSV)
SpeciesHuman
Sample typeNasopharyngeal or oropharyngeal swab
Assay typeRT-qPCR (reverse transcription quantitative PCR)
Assay format8-strip; 96-/384-well microtiterplate

Product resources

Norovirus direct RT-PCR

Detect and differentiate norovirus genogroups in one step.

The Norovirus direct RT-PCR test is designed to detect norovirus RNA after extraction of RNA from biological samples on a commercially available qPCR cycler.

Product specifications

Ref.-No.: 113

FeatureSpecifications
ApplicationIdentification of norovirus GI and GII
SpeciesHuman
Sample typeRNA extracted from anal swab
Assay typeRT-qPCR (reverse transcription quantitative PCR)
Assay format8-strip; 96-/384-well microtiterplate

Product resources

MRSA direct PCR

Immediate decision making where it is needed most.

The MRSA direct PCR kits detect methicillin-resistant Staphylococcus aureus (MRSA) directly from sample swab. After adding untreated patient sample to the reaction solution, the PCR analysis is carried out directly in the qPCR device.

Product specifications

Ref.-No.: 111

FeatureSpecifications
ApplicationIdentification of Methicillin-resistant Staphylococcus aureus (MRSA)
SpeciesGram-positive bacteria 
Sample typeNasopharyngeal/oropharyngeal or wound swab
Assay typeqPCR (quantitative PCR)
Assay format8-strip; 96-/384-well microtiterplate

Product resources

COVID-19 direct RT-PCR

Top choice for fast, complex COVID-19 discrimination analysis.

Our COVID-19 direct RT-PCR Kits are uniquely designed to detect SARS-CoV-2 RNA and one of the current COVID-19 mutation variant(s) (VOC: Y505H;L452R; N501Y mutation) in parallel directly from (an) unprocessed patient sample(s) on a commercial qPCR cycler.

Click on the arrow for more information or ordering.

COVID-19 direct RT-PCR Omicron is designed to detect SARS-CoV-2 RNA and the COVID-19 Omicron variant (Y505H mutation) in parallel directly from (an) unprocessed patient sample(s) on a commercial qPCR cycler.

Product specifications

Ref.-No.: FBC106

FeatureSpecifications
ApplicationIdentification of SARS-CoV-2 RNA and SARS-CoV-2 Omicron variant (Y505H mutation)
SpeciesHuman
Sample typeNasopharyngeal or oropharyngeal swab
Assay typeRT-qPCR (Reverse Transcription – quantitative PCR)
Assay format8-strip; 96-/384-well microtiterplate format

Product resources

Our COVID-19 direct RT-PCR Kit is designed to detect SARS-CoV-2 RNA directly from (an) unprocessed patient sample(s) on a commercial qPCR cycler.

Product specifications

Ref.-No.: FBC101

FeatureSpecifications
ApplicationIdentification of SARS-CoV-2 RNA
SpeciesHuman
Sample typeNasopharyngeal or oropharyngeal swab
Assay typeRT-qPCR (Reverse Transcription – quantitative PCR)
Assay format8-strip; 96-/384-well microtiterplate format

Product resources

Get in touch to receive detailed ordering information.

COVID-19 direct RT-PCRδ is designed to detect SARS-CoV-2 RNA and the COVID-19 delta variant (L452R mutation) in parallel directly from (an) unprocessed patient sample(s) on a commercial qPCR cycler.

Product specifications

Ref.-No.: FBC103

FeatureSpecifications
ApplicationIdentification of SARS-CoV-2 RNA and SARS-CoV-2 delta variant (L452R mutation)
SpeciesHuman
Sample typeNasopharyngeal or oropharyngeal swab
Assay typeRT-qPCR (Reverse Transcription – quantitative PCR)
Assay format8-strip; 96-/384-well microtiterplate format

Product resources

Get in touch to receive detailed ordering information.

COVID-19 direct RT-PCR+ is designed to detect SARS-CoV-2 RNA and the COVID-19 mutation N501Y in parallel directly from (an) unprocessed patient sample(s) on a commercial qPCR cycler.

Product specifications

Ref.-No.: FBC102

FeatureSpecifications
ApplicationIdentification of SARS-CoV-2 RNA and SARS-CoV-2 mutation N501Y
SpeciesHuman
Sample typeNasopharyngeal or oropharyngeal swab
Assay typeRT-qPCR (Reverse Transcription – quantitative PCR)
Assay format8-strip; 96-/384-well microtiterplate format

Product resources

Customise

Don’t worry if you haven´t found what you need! We are able to provide customised real-time PCR kits that meet your requirements.

Tell us about your application and one of our scientists will get in touch.

    Make a request for your
    COVID-19 direct RT-PCR kit

    Get in touch with us and we will contact you shortly.
    Our team will assist you to find the perfect product.

    *mandatory field

    Check this box to agree to our privacy policy. Your details will be treated confidentially and will not be transferred to third parties. We will not use them for any other purpose.

    Loading...

      Get informed about our new
      Lab direct RT-PCR kits

      Get in touch with us and we will contact you shortly.

      *mandatory field

      Check this box to agree to our privacy policy. Your details will be treated confidentially and will not be transferred to third parties. We will not use them for any other purpose.

      Loading...

      Your benefits with Lab direct

      Time saving

      Get your results in
      less than 1 hour.

      Euro Icon

      Cost saving

      No prior isolation/purification steps necessary.

      Contamination Icon

      Low contamination risk

      Handle the sample just once.

      Low failure susceptibility

      One-step-protocol facilitates easy (to follow) assay handling.

      No device limitations

      Result generation possible via various qPCR-cyclers.

      No format limitations

      Test can be performed from 8-strip to 96-/384-well format.

      The Lab direct qPCR one-step protocol

      1.
      Prepare reaction mix

      by mixing the provided
      ready-to-use solutions A and B.

      2.
      Add unprocessed sample

      to the reaction mix
      in 8-strip to 384-well format.

      3.
      Get your result

      in less than 1 hour and
      on any qPCR cycler.


      Use Lab direct
      together with CYCLE® Dx

      We are currently working on integrating our Lab direct assays to our CYCLE® Dx platform technology
      to provide highly sensitive near patient diagnostics.